Soil gas probes · A Coruña

Installation of soil gas probes in A Coruña

Three soil gas probes installed by Direct Push in an unpaved landscaped area, for gas sampling in the unsaturated zone.

Date
October 2026
Location
A Coruña
Technique
Soil gas probes
Probes installed
3
Maximum depth
2 m
Days on site
1

The work

In an unpaved landscaped area in A Coruña we installed three soil gas probes by Direct Push for gas sampling and monitoring in the unsaturated zone.

We drilled down to 2.00 metres with a track-mounted Direct Push rig, with no borehole wall collapse, and set the screen at 1.95 metres. The probes have a 2-4 mm silica gravel filter pack between 2.00 and 1.70 m, a bentonite seal between 1.70 and 0.10 m and a flush-mounted access box with a metal cover. Leak-tightness was checked with a multi-gas detector and the work took one day.