SVE · efficiency test · Seville

SVE efficiency test at a service station in Seville

Soil vapour extraction test in four dry wells in the unsaturated zone, with a van-mounted portable SVE unit.

Date
September 2026
Location
Seville
Technique
SVE · efficiency test
Contamination
Light hydrocarbons (VOCs)
Wells tested
4
Maximum depth
11.08 m
Days on site
1

The work

At a service station in Seville with light hydrocarbons (VOCs) in the unsaturated zone, we carried out a soil vapour extraction (SVE) efficiency test. We followed the ARC (2012) guidance criteria.

We tested 4 dry extraction wells, between 7.25 and 11.08 metres deep, in one working day. We used the SOILUTIONS van-mounted portable SVE unit, with PLC and touch screen, and a Busch Mink AV1252 vacuum pump. Each test lasted between 45 and 75 minutes, with flow rates of 35 to 70 m³/h and a vacuum of −380 to −760 mbar.